ERP3000 IVT RCD

Description

ERP3000 IVT RCD

model INVERTER ERP3000-IVT RCD
part-nr. 215487
OUTPUT TECHNICAL DATA
 
No-load voltage 230 Vac ± 10%
Load voltage 210÷240V CA
Frequency 50 Hz
Peak power 6000W
Continuous power 3000W
Output waveform Pure sine wave (THD < 3%)
Short-circuit protection Yes
Overload protection 3100÷3400W
 
INPUT TECHNICAL DATA
 
Operating voltage 11÷15 VdC
No-load consumption ≤ 1,6A
Low voltage alarm 10,5 VdC
Low voltage protection 9,5 VdC
High voltage protection 16 Vdc
Reverse polarity protection Yes (fuse)
INPUT TECHNICAL DATA – “MAINS MODE”  
Operating voltage 230V CA± 10%
Frequency 50 HZ
Input protection 20A Fuse
AC switching (Inverter / Mains Mode) ≤ 100 ms
GENERAL TECHNICAL DATA  
Efficiency ≥ 85%
Cooling Forced, automatically variable regulation
Operating temperature -15 ÷+40 °C
Overtemperature protection Yes
230V connection 1 × Schuko socket
Battery connection Terminals
RCD 20 A residual current circuit breaker
Remote panel MCI3 (opzionale)
Dimensions (mm) 422 x 300 x 93 (H)
Weight 6,3 kg
Integrated IVT function Yes (IEC C20 socket 16A)